Leave at least 6" between the drain line flow control fitting and solder joints. Allow to run until steady, clear and without air. Water Softeners: During operation, the normal user displays are time of day or gallons remaining before regeneration will occur. When troubleshooting a malfunctioning softener, you may want to run each regeneration step manually. 8 Start-up Instructions for Water Softeners: 8. The system will begin to regenerate immediately. When Manually Regenerating a Water Softener, How Long for Each Cycle. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles. 6 Once a manual regeneration is initiated, the unit will go into the FILL position. This manual is about a control valve to be used on water softeners or water filters.
  1. Water technologies water softener manual of style
  2. Water softener user manual
  3. Water technologies water softener manual.html
  4. Water technologies water softener manual available as ebook
  5. Water technologies water softener manual page
  6. Water technologies water softener manual.php

Water Technologies Water Softener Manual Of Style

4 Unit not tested for capacity at these flow rates. Where the drain empties into an overhead sewer line, a sink-type trap must be used. · Turn on water and check for leaks. NOTE: Hardness display shows "-nA-" if used as a filter. Drain Line Air Gap 2 pipe diameters or 25 mm (1 in) To Wastewater 4 Programming Procedures for Water Softeners: 1. Herb Kirchhoff has more than three decades of hands-on experience as an avid garden hobbyist and home handyman. Water technologies water softener manual page. You may experience a small amount of noise for a short period of time at 10:00 p. (with typical setting) on the night that regeneration is to occur.

Water Softener User Manual

If other displays do not appear, refer to manual. 7°C) · electrical 110 - 50/60Hz uninterrupted outlet · the tank should be on a firm level surface · current draw is 0. To initiate a manual regeneration at the preset delayed regeneration time, when the regeneration time option is set to normal or normal + on 0, press and release regen. The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic Service Wrench, (see page 7). When Manually Regenerating a Water Softener, How Long for Each Cycle? Adjust time of regeneration minutes with t and s buttons 9. When the system begins to regenerate, the display will change to include information about the step of the regeneration process and the time remaining for that step to be completed. System/Owners Manual. This position allows water to enter the brine tank until it reaches the proper level. There should be a rapid flow to the drain.

Water Technologies Water Softener Manual.Html

If the motor is not running fast enough or not running at all, the unit cannot work properly. Valve does not regenerate automatically but does when regen button is depressed 9. NOTE: The system regeneration sequence for softeners is in one of the two following sequences. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig. Once the unit is filled with water (step 2) then open the bypass. If you have any questions regarding your water conditioner, contact your local dealer or Greenway Water Technologies at the following: 400 Southgate Dr. Guelph, Ontario, Canada •Phone:1-888-5-WATER-0 •Fax:519-837-8913. Softeners / Conditioners. This noise is only the brine tank filling and at no time during this process will you be without treated water. Water technologies water softener manual available as ebook. SF2000 Quick Reference Guide.

Water Technologies Water Softener Manual Available As Ebook

Water Specialist WS1 and WS1. The water level is regulated by a float switch. Water technologies water softener manual of style. However, by running through these basic water softener troubleshooting steps, you'll have some idea to what's wrong. Close the bypass valve. Water will flow steadily at the drain. Pay special attention to codes for air gaps and anti-siphon devices. Water must flow into the brine/salt tank and then back out for the water softener to do its job.

Water Technologies Water Softener Manual Page

Untreated water is supplied to the building (Fig. The water treatment system will depressurize upon opening a tap in the building. MANUAL REGENERATION NOTE: For softeners, if brine tank does not contain salt, fill with salt and wait at least 2 hours before regeneration. ADVANCE CABINET SERIES WATER SOFTENER MANUAL. Solder joints near the drain must be done prior to connecting the drain line flow control fitting. Our detailed manuals and installation videos make most installations a breeze.

Water Technologies Water Softener Manual.Php

The second display is one of the following: days remaining or gallons remaining. To quickly exit any Programming, Installer Settings, etc., press set clock. Unplug the transformer so that the valve will not cycle to the next position. All other information will be stored in memory no matter how long the power outage. Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air. Capacity remaining is the number of gallons that will be treated before the system goes through a regeneration cycle. For the purpose of filling the softener, leave the unit in the bypass position until the 4th step, then repeat steps 1-6 with the unit full. If backwash is shown in window, proceed to step 2b. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being backsiphoned into the conditioner. Unplug transformer to keep the valve in the RINSE position. AM/PM toggles after 12:00. To do a double regeneration: 1.

Install an inlet shutoff valve and plumb to the unit's bypass valve inlet located at the right rear as you face the unit. Do not use a pipe wrench to tighten nuts or caps. If the building's electrical system is grounded to the plumbing, install a copper grounding strap from the inlet to the outlet pipe. The default is 20 with value ranges from 1 to 150 in 1 grain increments.

8 30 - 100 33 - 100 110 - 50/60 1" 13. This fitting is an elbow on the side of the brine tank. Guelph, Ontario, Canada ·Phone:1-888-5-WATER-0 ·Fax:519-837-8913 Preinstallation Instructions: The manufacturer has set the water treatment unit's sequence of cycles, cycle times, salt dose, exchange capacity, and gallon capacity. 1 8 Refill flow control (specify size) 1 not shown Elbow, 1/2" with nut & insert OP **Assembly includes refill flow control (specify size) 13 Replacement Parts: DRAIN LINE ASSEMBLY 3/4" Item No.