BullFrog 2001 Portable Spas. High CH (hard water) can cause cloudy water as well as rough scale build-up on the spa surface and equipment. Ooh no, something went wrong! If you have the M9, M8, or A9L models your spa will be equipped with 3 jet pumps. If the water appears cloudy, off color, has significant surface foam, or smells of excessive chlorine/bromine, the water needs to be treated or drained. WARNING: Make sure power is off to your spa prior to following spa filling procedure. For assistance in handling spa water chemistry, contact your authorized Bullfrog Spas dealer or another service center capable of performing a computerized water analysis.
  1. Bullfrog spa x series manual parts
  2. Bullfrog spas x series reviews
  3. Bullfrog spa x series manual of style
  4. Bullfrog a series spa
  5. Bullfrog spa x series manual installation
  6. Bullfrog spa owners manual
  7. Bullfrog x series spa

Bullfrog Spa X Series Manual Parts

BULLFROG SPAS OWNERS MANUAL QUICK REFERENCE To assist you with the installation and maintenance service of your new spa, please fill out the following information and keep it on hand for future reference. Step 5: Reinstall the filter cap(s) and filter snap cap. NOTE: Filter(s) must be cleaned with a filter cleaner/ degreaser before attempting to remove calcium and mineral deposits with any acidic based product Step 5: Reinstall cartridges(s) by aligning the cartridge slot with the filter core fin; reinstall the filter core cap(s), filter plate, and filter cap. The corner should fit tightly against the cabinet on both sides. Balance water by following STEPS a - d in order. 230V~/50Hz 16A, 16A Dual Service: Operation of spa is identical to single 32A service except that service is divided into two separate 16A services. · If you think the cartridge setting is too high, you can turn the dial setting down 1 number and monitor chlorine levels for a few days while maintaining water balance. Water Care Modes NOTE: Your spa will come from the factory in "Super Energy Savings" mode. Bullfrog Energy Consumption Comparisons (7). Safety Instructions & Warnings. Also, locate your spa in an environment that can withstand repeated exposure to water and the possibility of a major spill. Each device must be paired separately. Low CH (soft water) can stain the spa surface as well as cause corrosion to the spa and its equipment.

Bullfrog Spas X Series Reviews

Press once to turn lights on. Step 2: Remove door - Carefully pull bottom of door out toward you. Do not replace a suction fitting with one rated less than the flow rate marked on the original suction fitting. Screen Rotation/Mode Button. To maintain warranty protection, use only genuine Bullfrog Spas filter cartridge replacements. Changing Filter Cycles. Solution: Press any button to reset. Long term maintenance does require the replacement of the Carbon filter cartridge approximately every 24 months. The Lock option allows the user to partially or completely lock the keypad. Voltage Definitions: When reading these instructions, the term 120V~ refers to the 110-120V~ range of voltage, while the 230V~ term refers to the 220-240 range of voltage.

Bullfrog Spa X Series Manual Of Style

Spa will heat to normal set point during evening hours and on the weekend. 2l) of water · Non-chlorine Shock 5 teaspoons (25ml) of per 200 gallons (909. The Bullfrog EOS requires no special maintenance during normal usage. Use the and buttons to choose the setting that you wish to adjust, and select it by pressing the (Light) button. You are unique and your hot tub should fit your unique life. Spa will remain in Economy mode... How to Set Up Wifi on A Bullfrog Spa. 120V/60Hz Equipment. Once you have set your customized schedule, use the (Settings) button to go back to the Home/Status screen. Rinse thoroughly with cold water and air dry. Adjustable Jets A, R and S Series. Step 3: Try not to touch cover or rub anything on it while it is wet.

Bullfrog A Series Spa

Hardware Setup/Wiring Diagram A9L. WARNING: PEOPLE WITH INFECTIOUS DISEASES SHOULD NOT USE A SPA OR HOT TUB. NOTE: pH is affected by bather load, chemicals used, evaporation and the make-up of your source water so maintaining water balance regularly is important. FROG ppm NOTE e ® ned e so ot tubs ROG rking acously d fill etween dual ot neral sing ge ng carn the r best hen door/.

Bullfrog Spa X Series Manual Installation

Continue down the length of the corner and forcefully push it into each of the snaps until the corner is completely secured. Spa will heat to set point at all times on the weekend (Saturday & Sunday). Press the associated button. Refer to the following section to get details about the possible settings, accessories, and their detailed functionalities. Starting from the top force the first snap into place, if the corner has slipped down and is not flush with the top groove this is the best time to push it back up into place. Slide one end of the filter under the retention tabs and then press in and down to tuck the remainedr of the filter into the frame. Low TA can cause pH to be unstable. NOTE: The drain spout will not drain when fully extended. Your spa cover comes with a locking system that meets the ASTM F1346-91 Standard for Safety Covers, which when properly used, may satisfy certain fencing and gating requirements. Add balancing chemicals in small increments one at a time with the jets on and wait 6 hours before testing again and adding any Ste additional balancing chemicals.

Bullfrog Spa Owners Manual

Owner's Manual files are large and may take a few minutes to download. · To remove collected lotions or body oils, soak cartridge(s) in warm water with a filter cleaner or detergent. 0 (Macintosh) Adobe PDF Library 15. Step 3: Use a shop vacuum to vacuum the plumbing lines by placing the vacuum nozzle over each of the lower jet faces in the spa. Clean the cover fabric with a soft brush. Canadian Installations Only): 35. To clean or replace your filter cartridge(s), complete the following: CAUTION: Never operate spa with the filter(s) removed. Selecting the "Lock" option will lock all functions on the control while the "Partial Lock" option will allow jets, audio, and lights to remain funtional. Spa pump turns off during operation: Cause #1: Automatic timer has completed its 30 or 60 minute cycle. Follow the same procedure for the FROG @ease SmartChlor Cartridge into the other opening. Finnleo Outdoor Saunas.

Bullfrog X Series Spa

Within the Settings menu use the and buttons and then the (Light) button to select the Keypad Settings submenu. Note: The spa cover is an important part of maintaining spa water at the desired temperature. Step 7: Secure the cover to the spa utilizing the tie downs and locking system. This will clear the water of any micro-particulates that may be in the new water. The pH should measure 7. The Mode and Use the and buttons to choose between, 2, and no/other audio. If the national and local wiring rules permit, a GFCI Sub-Panel may be used to substitute the service disconnect, providing that it is located within the same parameters.

PH and Total Alkalinity need to be in the proper ranges for the FROG @ease System to work correctly. Menu keys remain unchanged, as well as the accessory keys in the main spa menu. WARNING: For products provided with a cord- connected, ground-fault circuit-interrupter, the GFCI must be tested before each use. Press "Source" to toggle between available sources. IF BLOWER IS INCLUDED, INSTALL AT LEAST 1 FOOT ABOVE MAXIMUM WATER LEVEL. Drain and refill hot tub as direct- ed by your hot tub manufacturer or every four months when FROG minerals need to be replaced. Use the (Light) button to Cancel the Standby function before the 30 minute period and restart the spa. SPA HEAT IN CONJUNCTION WITH ALCOHOL, DRUGS, OR MEDICATION CAN CAUSE UNCONSCIOUSNESS. Jet / Key 1 Press for jets LOW/HIGH/OFF If your spa is equipped with a second jet pump repeat the priming process for Pump 2 by pressing the "Jets 2" button once to turn on low speed and then a second time to turn Pump 2 on high. To avoid unnecessary system pressure never shut off all jets at the same time. Cleaning the Spa Cover. D d itial with ludes ne oduct 4. Step 2: Remove filter cap and filter plate. Spa Information Spa Model: Serial Number: Dealership: Dealer's Phone Number: Date Purchased: Date Installed: Contractor Information General 1.

CAUTION: Test the GFCI or RCD ( Residual Current Device) before each use of the spa. 6): Can cause scale build- up on the spa and its equipment, cloudy water, a prematurely dirty filter, and less effective chlorine sanitation.